Выпуск №30

Content of the issue
DOI: https://doi.org/10.37538/2224-9494-2021-3(30)-5-16

The results of the study of the grain-size composition and the grade of crushability of recycled crushed stone and their dependence on the strength of the original recycled concrete are presented. It is found that recycled crushed stone obtained from the original concrete of classes B10 - B30 does not meet the requirements of GOST 8267-93 for total residues on Ø25, Ø20, Ø5 and Ø2.5 sieves. Regardless of the strength of the original concrete, the main fraction of recycled crushed stone is grains with sizes from 12.5 to 20 mm. The strength (grade in terms of crushability) of the recycled crushed stone increases with an increase in the strength of the original concrete. The study of the main parameters of recycled crushed stone at the current moment has been carried out in an insufficient (for widespread introduction into production) volume and requires further study for the subsequent development of independent regulatory and technical documentation (or additions to the current regulatory and technical documents).


Keywords:

Breakage grade, grain size composition, non-waste of technological process, products of utilization of concrete and reinforced concrete designs, recycling, recycled (secondary) crushed stone, strength of concrete and recycling crushed stone

Authors:

Z. Beppaev, L. Astvasaturova, S. Kolodyazhniy, S. Vernigora, V. Lopatinskiy

Беппаев З.У., Аствацатурова Л. Х. , Колодяжный С. А., Вернигора С. А., Лопатинский В.В.

DOI: https://doi.org/10.37538/2224-9494-2021-3(30)-17-29

Research work was carried out at NIIZHB named after A.A. Gvozdev, one of the tasks of which was to study the influence of the conditions for stiff fixing supports on the parameters of the effective lengths of reinforced concrete columns with square and rectangular cross-sections assigned when calculating the
strength of normal sections. As part of the study, the influence of different values and directions of the angles of rotation of the fixing and their displacements was evaluated. The conducted computational and theoretical studies based on the analysis of experimental data showed that the method of determining
the effective lengths, adopted in domestic standards, can be improved. Based on the results of the research, proposals were formulated to take the results of
the work into account in the current regulatory framework. Taking into account the peculiarities of the conditions for fixing the structures considered in the work, which correspond to the nature of the work of monolithic columns and pylons, it is recommended to include the provisions of the proposed methodology in SP 430.1325800.2018, which applies to monolithic structural systems of buildings. The prepared proposals for the calculation are supposed to be included in the current regulatory documents as one of the possible options for determining the effective length of non-centrally compressed elements when calculating their strength.



Keywords:

Effective length, longitudinal force, non-centrally compressed elements, reinforced concrete, strength, stability

Authors:

S. Zenin, R. Shripov, O. Kudinov

Зенин С.А., Шарипов Р. Ш., Кудинов О. В.

DOI: https://doi.org/10.37538/2224-9494-2021-3(30)-30-40

The information about the new national standard GOST R «Self-compacting concrete
mixtures. Specifications», developed by the «Research Institute for Concrete and
Reinforced Concrete» named after A.A. Gvozdev, of JSC «Research Center of Construction», is presented. The standard applies to ready-to-use self-compacting concrete mixtures of heavy-weight, fine-grained, light-weight and reactive powder concretes, as well as fiber reinforced concretes, for the production of monolithic or
precast concrete structures and products, the shape and reinforcement of which makes it
difficult to place and compaction of an ordinary concrete mixture.
The standard establishes new terms and definitions, types and designations, uniform requirements for new technological characteristics (slump-flow, segregation,
viscosity and flowability), acceptance rules and test methods, production and transportation processes, control and evaluation procedures conformity of quality
indicators of self-compacting concrete mixes.

Keywords:

Flowability, segregation, self-compacting concrete mix, slump-flow, viscosity


Authors:

S. Kaprielov,  A. Sheyfeld, I. Arzumanov, I. Chilin

Каприелов С.С., Шейнфельд А.В., Арзуманов И.А., Чилин И.А.

DOI: http://doi.org/10.37538/2224-9494-2021-3(30)-41-50

The article presents examples of the use of ultra-high performance fiber reinforced concrete for load-bearing structures in Russia. Using this material with limits of compressive strength 150 MPa, flexural tensile strength 21 MPa, tensile strength 8.5 MPa, external post-tensioned structures of bridges and tanks are made instead of common solution with the steel anchors. Full-scale tests of anchors were carried out, which did not reveal signs of deformations and destruction of elements during the tension of strands, at the level of design and ultimate loads - before strands rupture. It was concluded that it is advisable to replace steel anchors with anchors from the material, which, with high strength characteristics, has ultra-low permeability and high frost resistance corresponding to the F21000 class. The estimated economic effect of such a replacement is determined by the reduced cost of these elements of structures made of ultra-high performance fiber reinforced concrete in comparison with steel.

Keywords:

Bridge superstructures strengthening, prestressing, post-tensioning, ultra-high performance fiber reinforced concrete

Authors:

M. Marchenko, I. Chilin, N. Selyutin

Марченко М.С., Чилин И.А., Селютин Н.М.

DOI: https://doi.org/10.37538/2224-9494-2021-3(30)-51-55

The article presents information about the changes made to the code of rules for the design of concrete structures reinforced with polymer composite reinforcement. New rules for the formation of relative deformations at the base point of a two-line diagram of concrete under axial tension, used to calculate reinforced concrete elements for the second group of limit states, are described. The rules for calculating re-reinforced structures of T-or I-beam cross-sections with a shelf in a compressed zone by the method of limiting forces are presented. The rules for taking into account the inelastic properties of concrete of the stretched zone when determining the elastic-plastic moment of resistance for the extreme stretched fibre of concrete with a rectangular cross-section and a T-shape with a shelf located in the compressed zone are clarified.

Keywords: 

Сrack resistance calculation, composite polymer reinforcement, concrete properties, resistance moment, strength calculation, structures

Author:

T. Muhamediev

Мухамедиев Т. А.

DOI: https://doi.org/10.37538/2224-9494-2021-3(30)-56-65

The impregnating compositions for increasing the strength of concrete surfaces are analyzed, standard methods for testing the physical and mechanical properties of concrete after its impregnation are considered. The need for a uniform classifier and methodology for assessing the quality of impregnation of concrete with various reinforcing materials has been pointed out.

Keywords:

Сomposition, concrete, hardening, impregnation, physical and mechanical properties, standard methods

Authors:

V. Remnev, L. Kosheleva, D. Ryzancev

Ремнев В. В., Кошелева Л. И., Рязанцев Д. Г.

DOI: https://doi.org/10.37538/2224-9494-2021-3(30)-66-77

In construction, thin-walled reinforced concrete spatial structures are used both for unique roofs of large-span buildings and for mass buildings of the pavilion type and small architectural forms. The most serious obstacle to the widespread application of economical thin-walled reinforced concrete structures is the shortcomings of the technology used for the manufacture and installation of prefabricated shell elements. The method of bending just formed flat flexible plates to give them a curved shape is one of the most promising technological methods that allow you to abandon the use of expensive metal forms of complex curved outlines, significantly simplify all production processes. The article describes the experience of research and development of structural decisions for spatial structures of building roofs with the use of unified rhombic elements made by the method of bending a flat just formed sheet on a flexible formwork.


Keywords:

Сasting technique, designing, ferrocement shell, reinforced concrete shell, rhombic unit, steel fiber concrete shell

Authors:

B. Sokolov, V. Titaev, D. Pashin

Соколов Б.С., Титаев В. А., Пасхин Д.В.

DOI: https://doi.org/10.37538/2224-9494-2021-3(30)-78-87

Experience in applying the standard 10060-2012 ‘Concrete. Methods for determining frost resistance’ shows the need to adjust the methods for determining frost resistance of concrete. Based on the performed by NIIZНB named after A.A. Gvozdev of research on frost resistance of concrete by the third accelerated method of GOST 10060, experimental data were obtained to clarify the freeze-thaw regime of concrete samples and the criterion for evaluating frost resistance by ultrasound speed.

Keywords:

Concrete, frost resistance, the criterion of frost resistance, freezing-thawing

Authors:

V. Stepanova, G. Chehniy, I. Parshina, S. Orehov

Степанова В.Ф., Чехний Г.В., Паршина И.М., Орехов С.А.

DOI: https://doi.org/10.37538/2224-9494-2021-3(30)-88-99

The results of studies of porosity, water absorption, moisture shrinkage and frost resistance of cellular concrete, which are some of the main factors determining the durability of cellular concrete enclosing structures manufactured using autoclave hardening technology, are considered. Methods for determining water absorption, moisture shrinkage and frost resistance are presented. The relationship between the moisture shrinkage and the capillary forces (the sum of the surface tension forces on the micromeniscs of liquid in the capillaries of cellular concrete), as well as the dependence of the shrinkage on the size (radius) of the capillary and gas pores of cellular concrete

Keywords:

Сapillary porosity, capillary suction, frost resistance, gas porosity, moisture shrinkage, vapor permeability, water absorption, water vapor diffusion

Authors:

V. Strockiy, A. Krohin, V. Savin

Строцкий В. Н., Крохин А. М., Савин В. И.

DOI: https://doi.org/10.37538/2224-9494-2021-3(30)-100-107


The article presents the results of studies of the fatigue strength of A500 class reinforcement by GOST 34028-2016 with various types of periodic profile. The data on the results of previously conducted experimental studies of the fatigue strength of various types of reinforcement are generalized and systematized, and the main factors affecting fatigue are established. Experimental data on strength and deformation characteristics under static and high-cycle loads of A500C class reinforcement with various types of periodic profile have been obtained. Based on the research results, proposals were made to improve the characteristics of the reinforcement and the periodic profile to increase its resistance to repeated cyclic loads and to amend the current regulatory documents.

Keywords:

Endurance limit, fatigue strength, periodic profile of reinforcement, reinforcement


Authors:

V. Terin, D. Klimov, A. Kvasnikov

Терин В.Д., Климов Д. Е., Квасников А.А.